Having trouble with your vacuum pump?

Select your problem below to reach us quickly, or read about common faults and maintenance intervals.

Quick Support

Select your problem and we'll get back to you

No long explanations needed. Pick your problem and a ready-made WhatsApp message opens.

Keep production running while your pump is repaired. A loaner pump (on consignment) can be supplied during repairs.
Request a Loaner Pump
FAQ

Common Problems

Possible causes by symptom. Contact our team for an accurate diagnosis.

My vacuum pump won't start. What should I do?

A vacuum pump that won't start can have many causes: a power outage, a faulty power cable or connection, an electric motor fault or jammed vanes.

To identify the exact cause, we recommend having the unit inspected and tested by an expert technician.

Ask us about this
Why is the vacuum level low?

A drop in vacuum level can result from various mechanical or system issues: worn or leaking seals on the covers, worn vanes, deformation of the rotor or housing, or clogged or leaking filters and connections on the suction line.

For an accurate diagnosis, we recommend having the pump checked by an expert technician.

Ask us about this
My pump is running very hot. Is that normal?

It is normal for vacuum pumps to get warm during operation, but excessive heat can be a sign of a fault. The rotor rubbing against the housing, vanes wearing the housing, bearing failure or other friction-related problems can all cause overheating.

In such cases, have the unit checked by qualified technical staff before it leads to a bigger failure.

Ask us about this
How often should the oil be changed?

The oil change interval depends on how intensively the pump is used. As a general guide:

  • Light use (under 8 hours a day): every 4,000 hours or once a year
  • Medium use (8–16 hours a day): every 2,000 hours or twice a year
  • Heavy use (over 16 hours a day): every 1,000 hours or every three months

When changing the oil, drain the old oil completely, clean the system and refill with the correct type of new oil. The oil filter and separator should also be checked and replaced if necessary.

Ask us about this
My pump is making an abnormal noise. What should I do?

Abnormal noises can have many causes: a blockage in the lubrication system, worn vanes, friction in the housing or rotor, bearing failure, or problems with the separator or oil filter.

For an accurate diagnosis, the unit should be checked by an expert technician and, if necessary, opened up and inspected in detail.

Ask us about this
When should I have periodic maintenance done?

Periodic maintenance should be carried out at the same intervals as oil changes to keep the vacuum pump running efficiently and reliably. Depending on usage, we recommend maintenance at approximately:

  • Pumps running 24/7: every 2,000 hours
  • Pumps running regularly through the week: every 4,000 hours
  • Less frequently used pumps: every 8,000 hours

Maintenance should include an oil change, filter and separator checks, inspection of the seals and a general review of the pump's operating condition.

Ask us about this
Will my production stop while my pump is being repaired?

It doesn't have to. While your pump is being repaired in our workshop, we can supply a suitable loaner pump to your facility on consignment. Once the repair is complete, your pump is tested and returned, and the loaner pump is collected.

Loaner pump availability depends on pump type, capacity and stock. Call us to check availability.

Ask us about this
Knowledge Base

General Information About Vacuum Pumps

Vacuum pumps are critical components that directly affect the performance of many industrial machines and are often called "the heart of the system". Although users often don't know the details, choosing the right type of vacuum pump and following a regular maintenance schedule are essential for machine efficiency and service life — and for keeping your business running without interruption. Vacuum pumps generally fall into three main groups:

1. Oil-Sealed Vacuum Pumps

Oil-sealed vacuum pumps use oil to seal the pumping chamber, which gives them high suction performance and makes them more powerful than other pump types. However, depending on operating hours, they require periodic maintenance at 2,000, 4,000 or 8,000-hour intervals.

Depending on the pump's condition, light or heavy maintenance may be needed. We strongly recommend that this work is carried out by experienced specialists.

2. Liquid Ring (Water) Vacuum Pumps

Liquid ring vacuum pumps create suction with a rotating ring of water, so they are specially designed to operate in contact with water. Various models are available for different applications.

Periodic maintenance suited to the way the pump is used is essential for maintaining performance and high efficiency.

3. Dry Vacuum Pumps

Dry vacuum pumps create suction with air alone, without oil or water in the pumping chamber. They include screw, claw, dry rotary vane and booster type models.

Since each model has a different operating principle and application, maintenance requirements should be assessed model by model.

Vacuum pumps are critical equipment used in industrial and scientific applications. They create a low-pressure environment by removing air or gas. Correct use and regular maintenance are vital for machine performance and service life. If a pump makes unusual or louder-than-normal noise during operation, this usually indicates a mechanical fault or a need for maintenance and should always be taken seriously.

Regular maintenance includes oil changes, filter cleaning, checking the seals, and monitoring operating temperature and vibration levels.

Correct installation is also essential for efficient operation: the pump should be placed in a suitable environment, vibration isolation should be provided and an appropriate power supply should be used.

Get in Touch

Having trouble with your pump?

Let's assess the fault together and, if needed, supply a loaner pump during the repair.

Call Us WhatsApp